Atto - Read - QD 4 - 4 kB - Gem. snelheid |
362,2 MB/s |
|
|
Atto - Read - QD 4 - 64 kB - Gem. snelheid |
549,1 MB/s |
|
|
Atto - Read - QD 4 - 1 MB - Gem. snelheid |
560,5 MB/s |
|
|
Atto - Write - QD 4 - 4 kB - Gem. snelheid |
310,7 MB/s |
|
|
Atto - Write - QD 4 - 64 kB - Gem. snelheid |
522,2 MB/s |
|
|
Atto - Write - QD 4 - 1 MB - Gem. snelheid |
544,1 MB/s |
|
|
AS SSD - Totaalscore |
1.162 |
|
|
AS SSD - Leesscore |
473 |
|
|
AS SSD - Schrijfscore |
436 |
|
|
AS SSD - Read - Sequential |
520,29 MB/s |
|
|
AS SSD - Read - 4K blokken |
32,05 MB/s |
|
|
AS SSD - Read - 4K blokken - 64 Threads |
389,29 MB/s |
|
|
AS SSD - Read - Access time |
0,049 ms |
|
|
AS SSD - Write - Sequential |
501,81 MB/s |
|
|
AS SSD - Write - 4K blokken |
70,61 MB/s |
|
|
AS SSD - Write - 4K blokken - 64 Threads |
315,66 MB/s |
|
|
AS SSD - Write - Access time |
0,049 ms |
|
|
Iometer - Database - QD1 |
28,4 MB/s |
|
|
Iometer - Database - QD1 (Iops) |
3.630 IOps |
|
|
Iometer - Database - QD2 |
44,6 MB/s |
|
|
Iometer - Database - QD2 (Iops) |
5.709 IOps |
|
|
Iometer - Database - QD4 |
61,3 MB/s |
|
|
Iometer - Database - QD4 (Iops) |
7.844 IOps |
|
|
Iometer - Database - QD8 |
69,1 MB/s |
|
|
Iometer - Database - QD8 (Iops) |
8.848 IOps |
|
|
Iometer - Database - QD16 |
70,6 MB/s |
|
|
Iometer - Database - QD16 (Iops) |
9.031 IOps |
|
|
Iometer - Database - QD32 |
70,1 MB/s |
|
|
Iometer - Database - QD32 (Iops) |
8.978 IOps |
|
|
Iometer - Fileserver - QD1 |
38,9 MB/s |
|
|
Iometer - Fileserver - QD2 |
65,1 MB/s |
|
|
Iometer - Fileserver - QD4 |
94,8 MB/s |
|
|
Iometer - Fileserver - QD8 |
110,6 MB/s |
|
|
Iometer - Fileserver - QD16 |
116,5 MB/s |
|
|
Iometer - Fileserver - QD32 |
116,7 MB/s |
|
|
Iometer - 4k aligned random read - QD1 |
24,43 MB/s |
|
|
Iometer - 4k aligned random read - QD1 (Iops) |
6.254 IOps |
|
|
Iometer - 4k aligned random read - QD2 |
48,268 MB/s |
|
|
Iometer - 4k aligned random read - QD2 (Iops) |
12.356 IOps |
|
|
Iometer - 4k aligned random read - QD4 |
94,319 MB/s |
|
|
Iometer - 4k aligned random read - QD4 (Iops) |
24.146 IOps |
|
|
Iometer - 4k aligned random read - QD8 |
173,734 MB/s |
|
|
Iometer - 4k aligned random read - QD8 (Iops) |
44.476 IOps |
|
|
Iometer - 4k aligned random read - QD16 |
306,075 MB/s |
|
|
Iometer - 4k aligned random read - QD16 (Iops) |
78.355 IOps |
|
|
Iometer - 4k aligned random read - QD32 |
340,283 MB/s |
|
|
Iometer - 4k aligned random read - QD32 (Iops) |
87.112 IOps |
|
|
Iometer - 4k aligned random write - QD1 |
58,04 MB/s |
|
|
Iometer - 4k aligned random write - QD1 (Iops) |
14.858 IOps |
|
|
Iometer - 4k aligned random write - QD2 |
212,611 MB/s |
|
|
Iometer - 4k aligned random write - QD2 (Iops) |
54.428 IOps |
|
|
Iometer - 4k aligned random write - QD4 |
275,513 MB/s |
|
|
Iometer - 4k aligned random write - QD4 (Iops) |
70.531 IOps |
|
|
Iometer - 4k aligned random write - QD8 |
352,587 MB/s |
|
|
Iometer - 4k aligned random write - QD8 (Iops) |
90.262 IOps |
|
|
Iometer - 4k aligned random write - QD16 |
353,56 MB/s |
|
|
Iometer - 4k aligned random write - QD16 (Iops) |
90.511 IOps |
|
|
Iometer - 4k aligned random write - QD32 |
343,177 MB/s |
|
|
Iometer - 4k aligned random write - QD32 (Iops) |
87.853 IOps |
|
|
Iometer - 1MB sequential read |
511,995 MB/s |
|
|
Iometer - 1MB sequential read (Iops) |
512 IOps |
|
|
Iometer - 1MB sequential write |
515,52 MB/s |
|
|
Iometer - 1MB sequential write (Iops) |
516 IOps |
|
|