Atto - Read - QD 4 - 4 kB - Gem. snelheid |
306,3 MB/s |
|
|
Atto - Read - QD 4 - 64 kB - Gem. snelheid |
549,1 MB/s |
|
|
Atto - Read - QD 4 - 1 MB - Gem. snelheid |
560,5 MB/s |
|
|
Atto - Write - QD 4 - 4 kB - Gem. snelheid |
277,0 MB/s |
|
|
Atto - Write - QD 4 - 64 kB - Gem. snelheid |
361,1 MB/s |
|
|
Atto - Write - QD 4 - 1 MB - Gem. snelheid |
357,9 MB/s |
|
|
AS SSD - Totaalscore |
1.040 |
|
|
AS SSD - Leesscore |
405 |
|
|
AS SSD - Schrijfscore |
425 |
|
|
AS SSD - Read - Sequential |
527,13 MB/s |
|
|
AS SSD - Read - 4K blokken |
33,97 MB/s |
|
|
AS SSD - Read - 4K blokken - 64 Threads |
317,95 MB/s |
|
|
AS SSD - Read - Access time |
0,039 ms |
|
|
AS SSD - Write - Sequential |
344,03 MB/s |
|
|
AS SSD - Write - 4K blokken |
96,84 MB/s |
|
|
AS SSD - Write - 4K blokken - 64 Threads |
293,72 MB/s |
|
|
AS SSD - Write - Access time |
0,038 ms |
|
|
Iometer - Database - QD1 |
43,8 MB/s |
|
|
Iometer - Database - QD1 (Iops) |
5.601 IOps |
|
|
Iometer - Database - QD2 |
77,9 MB/s |
|
|
Iometer - Database - QD2 (Iops) |
9.967 IOps |
|
|
Iometer - Database - QD4 |
102,4 MB/s |
|
|
Iometer - Database - QD4 (Iops) |
13.106 IOps |
|
|
Iometer - Database - QD8 |
150,3 MB/s |
|
|
Iometer - Database - QD8 (Iops) |
19.233 IOps |
|
|
Iometer - Database - QD16 |
187,4 MB/s |
|
|
Iometer - Database - QD16 (Iops) |
23.983 IOps |
|
|
Iometer - Database - QD32 |
207,3 MB/s |
|
|
Iometer - Database - QD32 (Iops) |
26.528 IOps |
|
|
Iometer - Fileserver - QD1 |
56,9 MB/s |
|
|
Iometer - Fileserver - QD2 |
91,3 MB/s |
|
|
Iometer - Fileserver - QD4 |
117,8 MB/s |
|
|
Iometer - Fileserver - QD8 |
164,6 MB/s |
|
|
Iometer - Fileserver - QD16 |
217,2 MB/s |
|
|
Iometer - Fileserver - QD32 |
256,7 MB/s |
|
|
Iometer - 4k aligned random read - QD1 |
28,558 MB/s |
|
|
Iometer - 4k aligned random read - QD1 (Iops) |
7.311 IOps |
|
|
Iometer - 4k aligned random read - QD2 |
55,899 MB/s |
|
|
Iometer - 4k aligned random read - QD2 (Iops) |
14.310 IOps |
|
|
Iometer - 4k aligned random read - QD4 |
78,533 MB/s |
|
|
Iometer - 4k aligned random read - QD4 (Iops) |
20.104 IOps |
|
|
Iometer - 4k aligned random read - QD8 |
149,337 MB/s |
|
|
Iometer - 4k aligned random read - QD8 (Iops) |
38.230 IOps |
|
|
Iometer - 4k aligned random read - QD16 |
260,06 MB/s |
|
|
Iometer - 4k aligned random read - QD16 (Iops) |
66.575 IOps |
|
|
Iometer - 4k aligned random read - QD32 |
364,49 MB/s |
|
|
Iometer - 4k aligned random read - QD32 (Iops) |
93.309 IOps |
|
|
Iometer - 4k aligned random write - QD1 |
88,925 MB/s |
|
|
Iometer - 4k aligned random write - QD1 (Iops) |
22.765 IOps |
|
|
Iometer - 4k aligned random write - QD2 |
168,397 MB/s |
|
|
Iometer - 4k aligned random write - QD2 (Iops) |
43.110 IOps |
|
|
Iometer - 4k aligned random write - QD4 |
225,231 MB/s |
|
|
Iometer - 4k aligned random write - QD4 (Iops) |
57.659 IOps |
|
|
Iometer - 4k aligned random write - QD8 |
283,63 MB/s |
|
|
Iometer - 4k aligned random write - QD8 (Iops) |
72.609 IOps |
|
|
Iometer - 4k aligned random write - QD16 |
325,199 MB/s |
|
|
Iometer - 4k aligned random write - QD16 (Iops) |
83.251 IOps |
|
|
Iometer - 4k aligned random write - QD32 |
319,697 MB/s |
|
|
Iometer - 4k aligned random write - QD32 (Iops) |
81.842 IOps |
|
|
Iometer - 1MB sequential read |
505,161 MB/s |
|
|
Iometer - 1MB sequential read (Iops) |
505 IOps |
|
|
Iometer - 1MB sequential write |
458,209 MB/s |
|
|
Iometer - 1MB sequential write (Iops) |
458 IOps |
|
|